Laser Scan Micrometer เลเซอร์สแกน
• Non-contact laser-based measuring system, mainly for outside diameter measurement. Suitable for delicate or moving workpieces. • Accuracy of ±0.5μm in the ø0.1 - ø25mm range can be achieved. It is highly suitable suited for pin gage measurement.
• Narrow range accuracy of ±(0.3+0.1 D)μm for high precision measurement. • Ultra-high repeatability of ±0.05μm. • The system consists of a measuring unit (LSM-902) and a display unit (LSM-6900).
Specifications Set Order No.
Measuring Unit External Dimensions
544-494 544-495*
544-496*
Measuring unit Type
mm mm
inch/mm
Applicable standards
JIS
IEC, FDA
Measuring range
0.1 to 25mm (.004 - 1.0”)
Resolution
0.01 to 10μm (selectable) (.000001 - .0005”)
±0.05μm (±.000002”)
Repeatability* 1 Accuracy* 2 (20°C) Positional error* 3 Measuring range* 4
Whole range ±0.5μm (±.000020”) Small range ±(0.3+0.1 D) [D:mm]* 5 ±(.000012+.001 D) [D:inch]
±0.5μm (±.000020”) ±1.5×25mm (±0.6x1.0”)
Scanning rate
800 scans/s
Laser wavelength
650nm (Visible) 56m/s (2240”/sec)
Laser scanning speed
Temperature Humidity
0 to 40°C
Operating environment
RH 35 to 85% (no condensation) *1: Determined by the value of ±2 ( : standard deviation) when measuring ø25mm at the interval of 1.28 sec. (average 1024 times). *2: At the center of the measuring range. *3: An error due to variation in workpiece position either in the optical axis direction or in the scanning direction. *4: The area given by [optical axis direction]×[scanning direction] *5: D=Difference in diameter between the master gage and workpiece (Unit: mm) Note : To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE. Display Unit Display
16-digit plus 11-digit fluorescent display, andguide message LED
Segment
1 to 7 (1 to 3, transparent) or 1 to 255 edges
Averaging times
Arithmetic average: per 1 to 2048/ Moving average: per 32 to 2048
Judgment
Selection from “target value + tolerance”, “lower tolerance + upper tolerance”, or “7 classes multilimit tolerance zone”.
Measurement mode Statistical analysis External dimensions
Standby, Single measurement, Continuousmeasurement Maximum, Minimum, Average, Dispersion, (S.D)
335 (W)×134 (H)×250 (D)mm
Power supply Standard I/F Optional I/F
100 - 240 V AC ±10%, 50W, 50/60Hz
RS-232C, Analog I/O
Digimatic code output unit (2-ch), 2nd I/O analog I/F, BCD I/F
Operating environment
0 to 40°C, RH 35 to 85% (no condensation)
Nominal setting, sample setting, selection of unnecessary digits, transparent object measurement, automatic measurement in edge mode, output timer, abnormal data elimination, SHL change, group judgment, simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection (dimension/position), zero-set/offset * Measuring unit dual connection, extra-fine line measurement, and some of the communication commands are not available.
Others