Reference Gauge
Surftest เครื่องวัดความเรียบผิว SJ-210 Series Other Functions
Specifications Type of detector
Standard drive unit type
Retractable drive unit type
Transverse tracing drive unit type
SJ-210 (0.75mN type)
SJ-210 (4mN type)
SJ-210 (0.75mN type)
SJ-210 (4mN type)
SJ-210 (0.75mN type)
SJ-210 (4mN type)
Model No.
Order No. inch/mm
178-561-11E 178-561-12E 178-563-11E 178-563-12E 178-565-11E 178-565-12E
X axis
16.0 mm
5.6 mm
Measuring range
Range
360 μm (-200 μm to +160 μm)
Z (Detector)
Range/Resolution
360 μm / 0.02 μm, 100 μm / 0.006 μm, 25 μm / 0.002 μm
Measuring speed
When measuring : 0.25mm/s, 0.5mm/s, 0.75mm/s When returning: 1mm/s 0.75mN type : 0.75mN / 2 μmR 60º, 4mN type : 4 mN / 5 μmR 60º
Measuring force/Stylus tip
Skid force
400mN or less
Applicable standards
JIS ‘82 / JIS ‘94 / JIS ‘01 / ISO ‘97 / ANSI / VDA
Assessed profile
Primary profile, Roughness profile, DF profile, Roughness profile-Motif
Ra, Rc, Ry, Rz, Rq, Rt, Rmax* 1 , Rp, Rv, R3z, Rsk, Rku, Rc, RPc, Rsm, Rz1max* 2 , S, HSC, RzJIS* 3 , Rppi, RΔa, RΔq, Rlr, Rmr, Rmr(c), R � c, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, Rpm, tp* 4 , Htp* 4 , R, Rx, AR, Possible Customize
Parameter
Graph analysis
Bearning area curve, Amplitud distribution curve
Filter
Gaussian, 2CR75, PC75 0.08, 0.25, 0.8, 2.5 mm
λ c
Cut off value
λ s* 5
2.5, 8 μm
Sampling length
0.08, 0.25, 0.8, 2.5 mm
×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10, arbitrary length (0.3 to16.0mm: 0.01mm interval)
×1,×2,×3,×4,×5,×6,×7,×8,×9,×10, arbitrary length (0.3 to 5.6mm: 0.01mm interval)
Number of sampling lengths
LCD dimensions Display language
36.7 × 48.9 mm
Japanese, English, German, French, Italian, Spanish, Portuguese, Korean, Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian, Turkish, Swedish, Dutch Vertical display: 1-parameter display / 3 parameter display / Trace display Horizontal display : 1-parameter display / 4 1-parameter display / Trace display (Horizontal display is available.) Measurement condition / Calculation result / GO / NG judgement result / Calculation result for each sampling length Assessed profile / Bearning area curve / Amplitud distribution curve / Environmental setting items
Measurement result display Printing functions * 6 (Dedicated printer is required separately)
External I/O
USB I/F, Digimatic output, printer output, RS-232C I/F, foot SW I/F Desired parameters can be selected for calculation and display.
Customization
GO/NG judgment* 7 Storing measurement condition
By Max value, 16% / Standard deviation
Save the conditions at power off
Function
Internal memory : Measurement condition (10 Set) Memory card (optional) : 500 measurement conditions, 10000 measured profiles, 500 display images, Text files (Measurement condition/Measured profile / Assessed profile / Bearning area curve / Amplitud distribution curve) Auto-calibration with the entry of numerical value /Average calibration with multiple measurement (Max. 5 times) is available. Two-way power supply : battery (rechargeable Ni-MH battery) and AC adapter Note 1 : Charging time : about 4 hours (may vary due to ambient temperature) Note 2 : Endurance: about 1000 measurements (differs slightly due to use conditions / environment) Auto sleep off function (10-600 sec.) * 8
Storage
Calibration
Power saving function
Power supply
Display unit
52.1 × 65.8 × 160 mm (sliding cover closed, detector not mounted)
Size (W×D×H)
Drive unit
115 × 23 × 26 mm (excluding the detector)
Mass
Approx. 500 g (Display unit + Drive unit, Standard detector)
12BAA303 Connecting cable* 9 178-605 Roughness specimen (Ra 1 μm) 12AAE643 Point-contact adapter 12AAE644 V-type adapter 12BAR344 Carrying case 12BAK700 Calibration stage Protective sheet for the display, AC adapter, Operation manual, Quick-reference manual, Warranty
12BAA303 Connecting cable* 9 178-601 Roughness specimen (Ra 3 μm) 12BAR344 Carrying case 12BAK700 Calibration stage Protective sheet for display AC adapter, Operation manual Quick- reference manual, Warranty
Standard Accessories
*1: Calculation is available only when selecting the VDA, ANSI, or JIS '82 standard. *2: Calculation is available only when selecting the ISO '97 standard. *3: Calculation is available only when selecting the JIS '01 standard. *4: Calculation is available only when selecting the ANSI standard. *5: Not available when selecting the JISm'82 standard *6: Order the SJ-210 printer ( 178-421 , Option accessory) separately. *7: Standard deviation only can be selected in ANSI. 16% rule cannot be selected in VDA. *8: Auto sleep function is invalid when AC adaptor is used. *9: For connection the calculation display unit and drive unit Note 1 : To denote your AC line voltage add the following suffixes (e.g. 178-560-11A ). A for 120V, C for 100V, D for 230V, E for 230V (for UK), DC for 220V (for China), K for 220V (for Korea)
JSR Entech Catalogue 188