JSR ENTECH Catalog

Reference Gauge

Surftest เครื่องวัดความเรียบผิว SJ-310 Series Other Functions

 Specifications Type of detector

Standard drive unit type

Retractable drive unit type

Transverse tracing drive unit type

SJ-310 (0.75mN type)

SJ-310 (4mN type)

SJ-310 (0.75mN type)

SJ-310 (4mN type)

SJ-310 (0.75mN type)

SJ-310 (4mN type)

Model No.

Order No. inch/mm

178-571-11E 178-571-12E 178-573-11E 178-573-12E 178-575-11E 178-575-12E

X axis

16.0 mm

5.6 mm

Measuring range

Range

360 μm (-200 μm to +160 μm) [14400 μinch to + 6300 μinch) 360 μm / 0.02 μm, 100 μm / 0.006 μm, 25 μm / 0.002 μm

Detector

Range/Resolution

Measuring speed

When measuring : 0.25mm/s, 0.5mm/s, 0.75mm/s When returning : 1mm/s 0.75mN type : 0.75mN / 2 μmR 60º, 4mN type : 4 mN / 5 μmR 90º

Measuring force/Stylus tip

Skid force

400 mN or less

Applicable standards

JIS ‘82 / JIS ‘94 / JIS ‘01 / ISO ‘97 / ANSI / VDA

Assessed profile

Primary profile, Roughness profile, DF profile, Roughness profile - Motif, W - Motif

Ra, Rc, Ry, Rz, Rq, Rt, Rmax* 1 , Rp, Rv, R3z, Rsk, Rku, Rc, RPc, Rsm, Rz1max* 2 , S, HSC, RzJIS* 3 , Rppi, RΔa, RΔq, Rlr, Rmr, Rmr(c), R � c, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, λa , λq , LO , Rpm, tp* 4 , Htp* 4 , R, Rx, AR, W, AW, Wx, Wte, WPossible Customize

Parameter

Graph analysis

Bearning area curve, Amplitud distribution curve

Filters

Gaussian, 2CR75, PC75 0.08, 0.25, 0.8, 2.5 mm

λ c

Cutoff value

λ s* 5

2.5, 8 μm

Sampling length

0.08, 0.25, 0.8, 2.5, 8 mm

x1, x2, x3, x4, x5, x6, x7, x8, x9, x10, Arbitrary (0.3 to16.0mm : 0.01mm Interval)

x1, x2, x3, x4, x5, x6, x7, x8, x9, x10, Arbitrary (0.3 to 5.6mm: 0.01mm Interval)

Number of sampling lengths

LCD dimensions Display language

117.8 x 88.2 mm

apanese, English, German, French, Italian, Spanish, Portuguese, Korean, Traditional Chinese, Simplified Chinese, Czech, Polish, Hungarian, Turkish, Swedish, Dutch 1-parameter display : one parameter measurement result 4-parameter display : four parameter measurement result profile display : one parameter measurement result and the measured profile Trace display : The ten latest measurement result using the same parameter

Measurement result display

Measurement condition / Calculation result / GO / NG judgement result / Calculation result for each sampling length Tolerance value / Assessed profile / Graphic curve / Bearning area curve / Amplitud distribution curve / Environmental setting information

Print functions

External I/O

USB I/F, Digimatic output, output, RS-232C I/F, External SW I/F Desired parameters can be selected for calculation and display. Max rule / 16% rule / Average rule / Standard deviation (1 σ , 2 σ , 3 σ )

Customization

GO/NG judgment function* 6 Storing measurement condition

Save the condition at power off

Function

internal memory : Measurement condition (10 set) Memory card (optional) : 500 measurement conditions, 10000 measured data, 500 statistic data, 10000 Text data, 1 backup of maching setting, the last ten traces (trace 10) Auto-calibration with the entry of numerical value /Average calibration with multiple measurement (Max. 12 times) is available. Two-way power supply : battery (rechargeable Ni-MH battery) and AC adapter Note 1 : Charging time : about 4 hours (may vary due to ambient temperature) Note 2 : Endurance : about 1500 measurements (differs slightly due to use conditions / environment) Auto sleep function (30 - 600 sec.) * 7

Storage

Calibration

Power saving function

Power supply

Display unit

275 × 109 × 198mm

Size (W×D×H)

Drive unit

115 × 23 × 26.7 mm (detector the mounted)

Mass

Approx. 1.8 g (Display unit + Drive unit + Standard detector)

12AAW066 Connecting cable *8 178-601 Roughness specimen (Ra 3 μm) 357651 AC Adapter 12AAA217 Nosepiece for flat surface 12AAA218 Nosepiece for cylindrical 12AAA216 Supporting leg 12BAK700 Calibration stage 12BAR507 Stylus pen 12BAL402 Protection sheet 270732 Printer paper (5 rolls) 12BAL400 Carrying case Phillips screwdriver, Strap for stylus pen, Operation manual, Quick-reference manual, Warranty

12AAW066 Connecting cable *8 178-605 Roughness specimen (Ra1μm) 357651 AC Adapter 12AAE643 Point-contact adapter 12AAE644 V-type adapter 12AAA216 Support feet set 12BAK700 Calibration stage 12BAR507 Stylus pen 12BAL402 Protection sheet 270732 Printer paper (5 rolls) 12BAL400 Carrying case Phillips screwdriver, Strap for stylus pen, Operation manual, Quick-reference manual, Warranty

Standard Accessories

*1: Only for VDA, ANSI, / JIS '82 standard. *2: Only for ISO '97 standard. *3: Only for JIS '01 standard. *4: Only for ANSI standard. *5: Not available for JIS '82 standard. *6: Standard deviation only can be selected in ANSI. 16% rule cannot be selected in VDA.

*7: Auto sleep function is invalid when AC adapter is used. *8: For connecting the calculation display unit and drive unit Note 1 : To denote your AC line voltage add the following suffixes (e.g. 178-570-11A ). A for 120V, C for 100V, D for 230V, E for 230V (for UK), DC for 220V (for China), K for 220V (for Korea)