JSR ENTECH Catalog

Measuring Tools

Vernier Caliper Nib Style Jaw with Fine Adjustment เวอร์เนีย

• Inside and outside measurements can be read directly from the upper and lower vernier scales. • The jaws have radiused measuring faces for accurate inside diameter (ID) measurement.

160-101

Fine adjustment

 Specifications Metric Order No.

Range

Accuracy Graduation Remarks

160-131

0 (20.1) - 450mm ±0.10mm

160-130 160-131 160-132 160-133 160-134

0 (20.1) - 600mm

without fine adjustment

0 (20.1) - 1000mm ±0.15mm 0 (20.1) - 1500mm ±0.22mm 0 (20.1) - 2000mm ±0.28mm

0.05mm

 Dimensions

* ( ): Minimum dimension in ID measurement

Unit : mm

with inside measurement vernier scale

Metric

Range

Accuracy Graduation Remarks

Order No. 160-127 160-128 160-101 160-104 160-110 160-113

0 (10.1) - 300mm ±0.04mm 0 (20.1) - 450mm ±0.05mm 0 (20.1) - 600mm ±0.05mm 0 (20.1) - 1000mm ±0.07mm 0 (20.1) - 1500mm ±0.1mm 0 (20.1) - 2000mm ±0.12mm

0.02mm —

* ( ): Minimum dimension in ID measurement

Range

DEFHLMR St 75 103 38 20 445 10 R5 12 3.8

with metric/inch double scale

Inch/Metric Order No. 160-176 160-186

0-300mm/0-12" 0-450mm* 0-450mm/0-18" 0-600mm/0-24" 0-1000mm* 0-1000mm/0-40" 0-600mm*

89 - 112 51 89 - 112 51 111 - 150 62.5 129 - 170 62.5 129 - 180 78

R10 R10 R10 R10 R10 R10 R10 R10 R10 R10

6 6 6 6 8 8 8 8

Range

Accuracy Graduation

Remarks

100

25 630 14.8

18

0-180mm/7" ±0.03mm 0-180mm/7" ±0.04mm 0 (10.1) - 300mm/12" ±0.04mm 0 (20.1) - 450mm/18" ±0.05mm 0 (20.1) - 600mm/24" ±0.05mm 0 (20.1) - 1000mm/40" ±0.07mm 0 (20.1) - 1500mm/60" ±0.1mm 0 (20.1) - 2000mm/80" ±0.12mm

With fine Adjustment With fine Adjustment +10mm/.394” to reading in inside measurement

100

25 780 14.8

18

160-150 160-151 160-153 160-155 160-157 160-159

140

32 1240 17

24

0.02mm/ .001”

0-1500mm*

180

32 1800 19

30

+20mm/.787” to reading in inside measurement

0-1500mm/0-60"

12 12

0-2000mm*

180

40 2300 23

30

0-2000mm/0-80" *: without fine adjustment

* ( ): Minimum dimension in ID measurement

Vernier Caliper SCM Type เวอร์เนีย High-precision reading for inside and outside measurement With “Fine adjustment carriage”, high precision is provided. Also various sizes are available with this vernier caliper.

Measurement of internal dimension

Measurement of external dimension

SCM15

• Since the tip of jaw is thin, high-precision reading is available for measurement of narrow part.

 SCM : Specifications

(Unit : mm)

Measuring length for outside dimension

Measuring length for inside dimension Instrumental error Weight A B C D E F G H J K

Order No.

0~150 0~200 0~300 0~400

5~150 5~200 10~300 10~400 14.5~450 14.5~500 14.5~600 20~1,000 20~1,500 25~2,000 25~2,500 25~3,000 25~4,000

170g 265 66 50 16 3 7 14 2.5 38 8 220g 320 77 60 17 3 7 15 2.5 46 8 460g 445 95 75 20 4 8 20 5 58 12 520g 545 95 75 20 4 8 20 5 58 12 900g 625 125 100 25 6 12.5 24.2 7.25 70 18 1.26kg 670 125 100 25 6 12.5 24.2 7.25 70 18 1.39kg 780 125 100 25 6 12.5 24.2 7.25 70 18 3.50kg 1250 172 140 32 8 15 32 10 95 24 6.50kg 1780 205 165 40 9 16 40 10 125 24 12.50kg 2325 250 200 50 11 20 50 12.5 150 25 14.50kg 2825 250 200 50 11 20 50 12.5 150 25 17.00kg 3325 250 200 50 11 20 50 12.5 150 25 25.00kg 4325 250 200 50 11 20 50 12.5 150 25

SCM15 SCM20 SCM30 SCM40 SCM45 SCM50 SCM60 SCM100 SCM150 SCM200 SCM250 SCM300 SCM400

±0.03

±0.04

0~450 0~500 0~600 0~1,000 0~1,500 0~2,000 0~2,500 0~3,000 0~4,000

±0.05

±0.07 ±0.12 ±0.16 ±0.22 ±0.26 ±0.40

*The minimum reading is 0.02 mm (division of 49 mm into 50 equal parts). For SCM400, however, the value is 0.05 mm.

JSR Entech Catalogue 45 jetco@jet.co.th

jet@jet.co.th

Powered by