Testing Instrument
ZTA•ZTS
FA Plus
● Sensor Separate Type Measured value by high speed sampling (Maximum 2000Hz) is displayed. The value is clear to see by an organic EL display. ※ It is not possible to connect an amplifier to plural load cells.
● Desktop Type Load Cell Amplifier
Accuracy ◎ High speed sampling : 2000Hz Follow rapid force change and Measurement Efficiency ◎ It is able to use as a part of factory automation equipment by using input and output signals. □ Size : W210×D160×H99mm □ Weight : Approx.1.5kg ※ It is not possible to connect an amplifier to plural load cells.
Example of combining an amplifier and a load cell. ZTA-DPU-500N
Measurement unit Sampling rate Display
N(kN), kgf(gf), ldf(ozf)
Load cell model
4 digit LTD
2000Hz (2000 data/ sec)
Peak hold, Comparator (OK/NG judgment), Setting sensitiveness and so on. USB/ Serial (RS232C)/ Analog (Approx. ±2V), Each comparator/ Overload caution Power cable, Spare fuse, USB cable, Driver CD-ROM, Load Capturing software FAP logger
Amplifier model (Please choose from ZTA or ZTS)
Functions Output function Accessory
※ When connecting an amplifier ZTA and DPU series
Load Cell โหลดเซลล์
Load Cell which converts sensing force to electric signal. It displays measuring force value by connecting an amplifier. Load cells are ideal for using under unique circumstances sucha s mounting into equipment, measurements at dangerous place.
for Compression and Tension Standard Type DPU Easy built-in shape to external equipment.
for Compression and Tension High Capacity Type DPU Easy built-in shape to external equipment.
for Compression and Tension Small Type SW1 It is possible to connect samples to the two sides of the sensor.
for Compression and Tension High Capacity Type SW3 It is possible to connect samples to the two sides of the sensor.
Measure force by mounting an attachment on the thread (the male screw part)
Measure force by mounting an attachment on the thread (the male screw part)
Measure force by fixation or connection with the female screw or eye bolts.
Measure force by fixation or connection with the female screw or eye bolts.
Capacity Accuracy
2N~500N
Capacity Accuracy
1000N~20kN ±0.2% F.S. or less
Capacity Accuracy
100~5000N
Capacity Accuracy
10kN~20kN
±0.2% F.S. or less
±0.5%F.S. or less
±0.5%F.S. or less
Approx. W58×D21×H71~W72×D21×H73mm
Approx. W58×D26×H130~W88×D42×H155mm
Size Approx.W40XD20XH40mm Cable Length Approx.0.5~4m (Curl cable)
Size
Approx.W80XD25XH80mm
Size
Size
Cable Length
Approx.5m
Cable Length
Approx.2m
Cable Length
Approx.3m
Order No. DPU-2N DPU-5N DPU-10N DPU-20N DPU-50N DPU-100N DPU-200N DPU-500N
Order No. DPU-1000N DPU-2000N DPU-5000N DPU-10kN DPU-20kN
Order No. SW1-100N SW1-200N SW1-500N SW1-1000N SW1-2000N SW1-5000N
Order No. SW3-10kN SW3-20kN
Capacity Thread
Capacity Thread 1000N Male Screw M6 P1.5 5000N 2000N 10kN N/A ※
Capacity Thread 100N Female Screw M6P1.0 200N 500N Female Screw M8P1.25 1000N 2000N Female Screw M10P1.5
Capacity Thread 10kN Female Screw M16P2.0
2N 5N
20kN ※ Please contact us if the users need the thread.
10N 20N 50N 100N 200N 500N
Male Screw M6P1.0
20kN ※ There is no thread on the load cell head while it equips a female screw M18 P1.5 Depth 22. The thread is able to attach on the head optionally.
5000N ※ Please contact us if the users need the thread.
JSR Entech Catalogue 523 jetco@jet.co.th
jet@jet.co.th