JSR ENTECH Catalog

Measuring Tools

Measurement Data Management Convenient data collection tool and quality control software Digimatic Gage/PC Data Input Device USB Input Tool Direct

A data collection tool that offers simple and popular operability (HID connection) and optional software to input data to Microsoft Excel at a reasonable price. A more sophisticated way to improve operational efficiency. Use USB-ITN standalone as a dedicated interface for Digimatic indicators compatible with HID keyboard devices. In common with the popular model IT-016U, this device is capable of entering measurement data to Microsoft Excel or a memo pad. Application example: using USB-ITN standalone to input data while selecting the data entry point flexibly during a measurement whose procedures cannot be determined in advance (such as the inspection of items or trial products with few measurements or without repeated procedures). Using USB-ITN in combination with dedicated options If you need more than just the ability to load the measurement data to Excel, the optional software USB-ITPAK can create a data input procedure to an Excel sheet to improve the operational efficiency of repeated inspections. Application example: using USB-ITN in combination with USB-ITPAK V2.1 to improve the operational efficiency of daily inspections such as sampling tests or complete inspections of mass-produced product. Input data to the PC with the push of a button. USB Input Tool Direct is automatically recognized as a HID* keyboard

USB-ITN

Main specification • Output compatibility: USB1.1 and USB2.0 •Supporting driver software : Switchable between 2 items below (1) When using standalone: HID keyboard device* (2) When using with USB-ITPAK V2.1 : Virtual COM port (VCP) • Communication speed: 12 Mbps (Full Speed) • Power supply: USB bus power • Mass: 59 g • USB2.0 certificate • Conforms to EMC Directives. * Since this device is compatible with Windows standard driver software, dedicated driver software is not required.

device (standard driver of Windows) by connecting it to a USB port. * Human Interface Device

The result is the same as typing a

number from the keyboard and pressing Enter.

Just press the data button to send the displayed value to the PC.

USB Input Tool Direct

System Configuration

Digimatic gages

USB Input Tool Direct USB-ITN

PC USB-ITPAK V2.1 (optional)

Gage selector 3 (optional) Note: Only connectable with USB-ITN-D.

Foot Switch (optional)

USB-FSW (optional)

C

USB Input Tool Direct USB-ITN Connector shape A B C D Type Order No. Data switch Cable length: 2 m

Connection port

Connector is plugged into a USB port on a PC

USB socket (Type A)

Digimatic caliper

System Environment • Hardware: PC with USB socket (Type A) • Supporting OS: Windows 2000 SP4 Windows XP SP2 (or later) Windows Vista Windows 7 Windows 8/8.1 Windows10 • Soft ware: Programs supporting keyboard input (Excel, Word, memo pad, etc.) Connection with USB-ITPAK is not available.

Connect the Digimatic connector to the gage

B

A 06AFM380A B 06AFM380B C 06AFM380C D 06AFM380D E 06AFM380E F 06AFM380F G 06AFM380G

Digimatic micrometer

F

E F G

– – – –

Digimatic indicator

Data loading methods • Data switch on the input tool (Type A/B/C only)

Foot Switch (optional)

Option for USB-ITN USB Foot Switch Adapter USB-FSW

Measurement Data Collection Software USB-ITPAK V2.1 (optional) 06AFM386

937179T

06ADV384

Cable length: 2 m

• Data switch on the measuring gage • Command transmission from a PC* * Only available when using USB-ITPAK V2.1 (1) Icon operation

Note: • When using a foot switch in combination with USB-ITN , the optional USB-FSW and USB-ITPAK V2.1 are required. • When the measuring gage and USB-ITN have no data pushbuttons, the optional USB-ITPAK V2.1 is required.

(2) Function key operation (3) Foot switch operation One of the above operations

JSR Entech Catalogue 1 jetco@jet.co.th