JSR ENTECH Catalog

L ist of C ontents

M easuring T ools

Caliper

Internal and External Caliper

Digital and Dial Gauges

Mitutoyo Measuring software and Cable 1-16

Micrometer 17-37

38-63

64-71

72-102

Bore Gauge and Holetest 126-137

Depth Gauge

Dial test Indicator

Thickness Gauges

Height Gauges

103-115

116-125

138-150

151-160

Stand

Precision Measuring Instrument

Optical Instrument

Gauge Block 221-228

Hardness Block

161-180

181-208

209-220

229

Calibration Standard Equiptment

Pin / Ring / Plug / Thread Guage Plug

Taper Gauges

Other Gauges

Feeler Gauges

230-266

267-272

273-276

277-297

298-303

Scale 353-359

Survey Tools 315-326

Scriber and Others

Levels

Standard Tools

304-314

327-338

339-352

JSR Entech Catalogue A

jet@jet.co.th

jetco@jet.co.th

L ist of C ontents

Magnetic Tools

Carpenter Tools

Precision Levels

Magnetic Chuck/Block Magnetic Holder/Stand

Protractors and Angle

369-381

382-385

386-392

389-407

360-368

Magnetic Sheet

Magnetic Lifter

Magnetic Pick up Tools

Magnetic Seperator

Magnetic Welding Tools

425-426

427-430

413-418

408-412

419-424

Testing Instrument

Multimeters 437-440

Clamp Meters

Detector

Phase Detector

Demagnetizer

441-442

443-444

445-446

431-436

Lab Testing Instrument 481-490

Test Insturment for Environment 472-480

Thermo / hygrometer 447-467

Data Logger 468-471

Hardness Tester 491-502

Stopwatch / Timer / Counter 507-513

Weight 514-512

Torque Gauge 540-562

Force Gauge 518-539

Thickness Gauge 503-506

JSR Entech Catalogue B jetco@jet.co.th

jet@jet.co.th

L ist of C ontents

Cutting Tools

Drill 581-610

Diamond Tools 563-573

Step Drill 616-618

Counterbore 611-615 / 619-620

Center Dril 574-580

Countersinks/ Chamfer Tools 646-649

Endmill 621-645

Carbide Bur 665-672

Deburring 650-664

673-675 Air Grinder

759-762 Knurling Tools

738-758 Reamer

704-737 File

681-703 Brush

676-680 Fiber Stone

Machine Tools

Positioning Tool

773-796 Taps and Dies

797-805 Thread Repair Tool

Holders 806-836

763-772 Cutters

837-842

Airgun 865-868

Coolant Hose 862-864

Standard Tools & Jig Fixtures 846-861

Live Center 843-844

Machine Vise 845

JSR Entech Catalogue C

jet@jet.co.th

jetco@jet.co.th

L ist of C ontents

Hand Tools

Tool Trolleys and Tool Box 909-922

898-908 Grease Guns & Tyre Inflaters

Chemical Spray 870-876

877-896 Spray Gun + Pump

897 Coupler

Airtool, Ratchets and Sockets 973-1007

Punches, Chisels and Hammers 1054-1073

Pliers 1008-1053

Wrenches 936-972

Tool Set 923-935

Clamping Tools and Lifting Clamps 1124-1153

Screwdriver 1074-1123

Piping Tools 1161-1172

Puller 1154-1160

Hydraulic Equipment

Other

Hydraulic Jacks + Hand and Electric Pumps

Bottle Jacks

Other 1173-1178

1179-1222

1223 - 1231

JSR Entech Catalogue D jetco@jet.co.th

jet@jet.co.th

Measuring Tools

Measurement Data Management Convenient data collection tool and quality control software Digimatic Gage/PC Data Input Device USB Input Tool Direct

A data collection tool that offers simple and popular operability (HID connection) and optional software to input data to Microsoft Excel at a reasonable price. A more sophisticated way to improve operational efficiency. Use USB-ITN standalone as a dedicated interface for Digimatic indicators compatible with HID keyboard devices. In common with the popular model IT-016U, this device is capable of entering measurement data to Microsoft Excel or a memo pad. Application example: using USB-ITN standalone to input data while selecting the data entry point flexibly during a measurement whose procedures cannot be determined in advance (such as the inspection of items or trial products with few measurements or without repeated procedures). Using USB-ITN in combination with dedicated options If you need more than just the ability to load the measurement data to Excel, the optional software USB-ITPAK can create a data input procedure to an Excel sheet to improve the operational efficiency of repeated inspections. Application example: using USB-ITN in combination with USB-ITPAK V2.1 to improve the operational efficiency of daily inspections such as sampling tests or complete inspections of mass-produced product. Input data to the PC with the push of a button. USB Input Tool Direct is automatically recognized as a HID* keyboard

USB-ITN

Main specification • Output compatibility: USB1.1 and USB2.0 •Supporting driver software : Switchable between 2 items below (1) When using standalone: HID keyboard device* (2) When using with USB-ITPAK V2.1 : Virtual COM port (VCP) • Communication speed: 12 Mbps (Full Speed) • Power supply: USB bus power • Mass: 59 g • USB2.0 certificate • Conforms to EMC Directives. * Since this device is compatible with Windows standard driver software, dedicated driver software is not required.

device (standard driver of Windows) by connecting it to a USB port. * Human Interface Device

The result is the same as typing a

number from the keyboard and pressing Enter.

Just press the data button to send the displayed value to the PC.

USB Input Tool Direct

System Configuration

Digimatic gages

USB Input Tool Direct USB-ITN

PC USB-ITPAK V2.1 (optional)

Gage selector 3 (optional) Note: Only connectable with USB-ITN-D.

Foot Switch (optional)

USB-FSW (optional)

C

USB Input Tool Direct USB-ITN Connector shape A B C D Type Order No. Data switch Cable length: 2 m

Connection port

Connector is plugged into a USB port on a PC

USB socket (Type A)

Digimatic caliper

System Environment • Hardware: PC with USB socket (Type A) • Supporting OS: Windows 2000 SP4 Windows XP SP2 (or later) Windows Vista Windows 7 Windows 8/8.1 Windows10 • Soft ware: Programs supporting keyboard input (Excel, Word, memo pad, etc.) Connection with USB-ITPAK is not available.

Connect the Digimatic connector to the gage

B

A 06AFM380A B 06AFM380B C 06AFM380C D 06AFM380D E 06AFM380E F 06AFM380F G 06AFM380G

Digimatic micrometer

F

E F G

– – – –

Digimatic indicator

Data loading methods • Data switch on the input tool (Type A/B/C only)

Foot Switch (optional)

Option for USB-ITN USB Foot Switch Adapter USB-FSW

Measurement Data Collection Software USB-ITPAK V2.1 (optional) 06AFM386

937179T

06ADV384

Cable length: 2 m

• Data switch on the measuring gage • Command transmission from a PC* * Only available when using USB-ITPAK V2.1 (1) Icon operation

Note: • When using a foot switch in combination with USB-ITN , the optional USB-FSW and USB-ITPAK V2.1 are required. • When the measuring gage and USB-ITN have no data pushbuttons, the optional USB-ITPAK V2.1 is required.

(2) Function key operation (3) Foot switch operation One of the above operations

JSR Entech Catalogue 1 jetco@jet.co.th

jet@jet.co.th

Measuring Tools

USB Keyboard Signal Conversion Type IT-016U The IT-016U, a popular USB input tool that enables easy data recording. Allows you to perform inspection work more efficiently. The IT-016U is equipped with a connector socket for a push-button or switch-foot operation. Functional improvements include : • A bigger, easy-to-press data switch. Size increased from ø4 mm to ø18 mm. Durability of the push button increased from 1 million to 10 million operations. • May be used with optional software USB-ITPAK V2.1. Enables efficient routine inspection work, for example, in mass production. RS-232C Communication Conversion Type IT-007R Input tool for RS-232C communication best suited for communication control of the software! Control is available by transmitting data request commands via RS-232C. F or example, production engineers can create communication programs to load the measurement data by transmitting a command from the PC. This product is a compact and low-cost RS-232C communication interface, which is convenient when it is installed in a machine tool or dedicated device to feed back measurement data. Measurement Data Management Convenient data collection tool and quality control software Measurement Data Input Unit Input Tool SERIES IT-016U/IT-007R IT-016U

Specifications of IT-007R RS-232C Communication • Output specification : RS-232C compliant Communication method : Full duplex Communication speed : 2400bps (fixed) Bit configuration : Start bit 1 Data length 8 (Most significant bit, 0 (fixed)) Parity, None Stop bit 1 Flow control: None Home position: DCE (modem definition) • Data format

IT-007

• Data request signal Data can be output by transmitting a character from the PC. • Connector specification and power supply from the PC This product operates while accumulating the power sup - plied from the PC. A second or more input interval is required. Pin No. Symbol in/out Description of functions 1 (N.C.) — No connection 2 RXD OUT Data output from this product to the PC 3 TXD IN Data input from the PC to this product 4 DTR IN +12 V power supply from the PC* 5 GND — Ground 6 DSR OUT Not used 7 RTS IN +12 V power supply from the PC* 8 CTS OUT Not used 9 (N.C.) — No connection * "4" and "6", "7" and "8" are short-circuited with each other inside this product. * When connecting to a sequencer, a power supply is required. Input voltage : Supplied in the range 6 V-16 V Power supply terminal: Supplied to pins 4 and 7

Main Specifications of IT-016U Supported driver software : Changeable between two types Output specification : USB2.0 or USB1.0 (1) Stand-alone: HID keyboard device* (2) Using USB-ITPAK V2.1: Virtual COM port (VCP) Communication speed: 12 Mbps (Full Speed) Power supply : USB bus power USB2.0 certificate Conforms to EMC Directives * This product is compatible with the standard driver software for Windows. No dedicated driver software is required.

The HID keyboard device (standard driver software for Windows) is automatically recognized when connected to a USB port. * HID (Human Interface Device)

System Configuration

Connecting cable (optional) Connecting cable (optional)

Switch box (optional)

Digimatic gage

Input tool

PC

C

Foot switch (optional) Connector shape A

USB keyboard signal conversion model Model: IT-016U 264-016-10

Connection port

Connect the unit toa USB port of the PC

B C D E F G

USB socket (Type A)

Digimatic caliper

Connector 7 types (A to G) + 4 L types

Connect the Digimatic connector to the gage

System Environment • Hardware: PC withUSB socket (Type A) • Supporting OS:

B

(1)

(2)

Digimatic micrometer

Cable length: 1 m or 2 m

F

Windows 98SE Windows Me Windows 2000

Windows XP Windows Vista Windows 7

Windows 8 Windows 8.1 Windows 10

(1)

• Software: Programs supporting keyboard input (Excel, Word, memo pad, etc.) USB-ITPAK V2.1 (optional)

Digimatic indicator

Foot switch (optional)

937179T

RS-232C communication conversion type Model: IT-007R 264-007

(2)

Serial port

Connecting cable 2 m

Connect the unit to a serial port of the PC

D-sub 9 pin

Gage selector 3 (optional)

(2) (1)

939039

System Environment • Hardware: PC or sequencer with a serial port (D-sub 9 pin) • Software: A program compatible withthe RS- 232C communication (such as a hyper terminal) is required.

This selector can connect up to 3 measuring gages and switching is available with the slide switches without changing connecting cables. Connecting cable (length : 1 m) between two input tools is a standard accessory (936937).

Data output is available by transmitting data request commands from the PC.

JSR Entech Catalogue 2

jet@jet.co.th

jetco@jet.co.th

Measuring Tools

Measurement data wireless communication system U-WAVE-TC/TM (U-WAVE fit) • Data from tools with Digimatic output function can be sent to a PC via wireless communication. • With functions and performance inherited from U-WAVE-T, the compact and thinner design provides better fitting to an instrument and improved operability, which enables further improvement of efficiency. • The data interface function of the U-WAVE-R standard accessory software enables data input to commonly available software (Microsoft Excel, Notepad, etc.) by keyboard input. • USB-ITPAK V2.1 supports U-WAVE! Loading multiple measurement data into separate Excel sheets, or simultaneous measurement using the special event drive is now available without the need for macro programming yourself. (Automatic loading in a certain interval is available with a timer function.) Measurement Data Management Convenient data collection tool and quality control software

U-WAVE-TC/TM (U-WAVE fit) System Communication Specifications • Wireless communication

Wireless specifications Wireless communication distance Wireless communication speed Transmission output

IEEE802.15.4 base

Approx. 20 m (line of sight)

250 kbps

2.5 mW (4 dBm) or less

DS-SS (Direct Sequence - Spread Spectrum) Resistant to interfering signals and noise 2.4 GHz band (ISM band: Universal frequency)

Modulation method

Communication frequency

Used band 15 channels (2.405 to 2.475 GHz at intervals of 5 MHz) The noise search function avoids interference with other communication devices. Note : To use U-WAVE-TC/TM , the conformity to the radio law of each country is required. If you use this product outside the country of purchase, please contact your dealer or nearest Mitutoyo sales office.

U-WAVE system configuration

Standard accessory software enables data load to Microsoft Excel, etc.

U-WAVE-TC/TM Transmits measurement data to U-WAVE-R.

U-WAVE-TM

U-WAVE-TC

Refer to the U-WAVE Brochure (No. E12000) for more details.

U-WAVE-R A maximum of 100 Digimatic gages can be connected. Loads the data received from U-WAVE-TC/TM to a PC via USB.

Main specifications of U-WAVEPAK • Setup of dedicated driver software (USB and virtual COM port) • Initial setting of ID number and frequency selection (required only once for the first time) • Load data to Microsoft Excel or Notepad through the data interface function

■ U-WAVE-R Receives data from U-WAVE-TC/TM, U-WAVE-T and loads to a PC via USB. Model U-WAVE-R Order No. 02AZD810D Power supply USB bus power system Number of U-WAVE-R units thatcan be connected to one PC Up to 16 Number of U-WAVE-T units that can be connected Up to 100 External dimensions 140×80×31.6mm Mass (g) 130

U-WAVEPAK software (standard accessory) System Environment: Compatible OS Windows 2000 Professional (SP4 or later)* Windows XP Home Edition (SP2 or later)* Windows XP Professional (SP2 or later)* Windows Vista*, Windows 7*, Windows 8/8.1* Windows 10* * Revision history (U-WAVEPAK) Ver1.010 or later is compatible with 32/64-bit OS. Ver1.020 or later is compatible with Windows 8. Ver1.021 or later is compatible with Windows 8.1. Ver1.022 or later is compatible with Windows 10.

Connectability confirmed for tablet PC • Microsoft Surface Pro 6 (the version whose operation on Windows10 Professional is confirmed) • Required environment : DVD drive (required for installation), USB port ×2 ports or more Note : Cannot be connected to a device other than a PC (such as DP-1VA LOGGER, PDA, or controller).

JSR Entech Catalogue 3 jetco@jet.co.th

jet@jet.co.th

Measuring Tools

Measurement Data Wireless Communication System U-WAVE-TCB / TMB (Mitutoyo Bluetooth ® U-WAVE) • Bluetooth ® communication allows for wireless transmission of measurement data from digimatic micrometers and calipers to PCs, smartphones, tablets and other such terminals. • More compact and thinner for a better fit with Digimatic gages, and featuring improved operability and performance inherited from its predecessor, U-WAVE- TCB / TMB is now available with Bluetooth ® wireless technology. No receiver is required, and one PC can conect up to seven units of Mitutoyo Bluetooth ® U-WAVE. Dust / water-proof models are also available for arduous shop floor usage. • Bluetooth ® communication not only allows cost reduction, as it does not require the conventional dedicated receiver unit, but it also improves operability. • The application software for transferring measurement data to smartphones and tablets, or the application U-WAVEPAK-BM (English version only) is available at app stores (Google Play, Apple Store) for download. U- WAVEPAK-BM Measurement Data Management Convenient data collection tool and quality control software

Wireless communication Bluetooth ® 4.2 Low Energy Wireless communication distance Approx. 16 m (line of sight) Approx. 10 m (in a factory environment) U-WAVE-TCB/TMB (Mitutoyo Bluetooth ® U-WAVE) System Communication Specifications • Wireless Communication Specifications

Transmission output Modulation method Communication frequency

3.2 mW (5 dBm) or less (Class2) FH-SS (Frequency-hopping spread spectrum)

2.4 GHz band Note 1 To use U-WAVE-TCB/TMB , conformity to the radio law of each country is required. Please contact your dealer or nearest Mitutoyo sales office. Note 2 U-WAVE-TCB/TMB is not compatible with U-WAVE fit , for which communication specifications are different. Optional Accessories Model No. USB-ITPAK V2.1 Order No. 06AFM386 Compatible OS (Windows) 10 (64 bit) Compatible Excel version 2016 (The operation with Excel for MAC OS is not guaranteed.) Note : Refer to pages A-22 to A-24 for details of USB-ITPAK V2.1

USB dongle must be connected to the PC runningthe software.

Bluetooth ® communication not only allows cost reduction, as it does not require the conventional dedicated receiver unit, but it also improves operability.

JSR Entech Catalogue 4

jet@jet.co.th

jetco@jet.co.th

Measuring Tools

Measurement Data Wireless Communication System U-WAVE-TMB/TCB (Mitutoyo Bluetooth ® U-WAVE) Measurement Data Management Convenient data collection tool and quality control software

Transmitter/Receiver

264-626

264-625

 Specifications

For Digimatic micrometers

For Digimatic calipers

Order No.

264-626

264-627

264-624

264-625

U-WAVE-TMB (IP67 type dust / water-proof)

U-WAVE-TCB (IP67 type dust / water-proof)

U-WAVE-TMB (Buzzer type)

U-WAVE-TCB (Buzzer type)

Model

Protection level

IP67 LED

N/A

IP67 LED

N/A

Data reception indication

LED, Buzzer

LED, Buzzer

Power supply

Lithium battery CR2032×1

Battery life

Approx. 1 year under normal conditions of use, but varies according to usage.

Mass (g)

18

02AZF310

02AZF300

Choose a connecting unit compatible with your gage. Order No. 02AZF310

02AZF300

Protection level

IP67

N/A

Data reception indication

6

Mass (g)

Lithium battery CR2032×1

U-WAVE-TCB/TMB (for dust / water-proof type)

U-WAVE-TCB (for standard type)

Connecting unit

Compatibility of measuring tool and unit

Assembled appearance

Connecting unit

Transmission unit

264-627 U-WAVE-TMB (Buzzer type)

Standard

02AZF310

264-626 U-WAVE-TMB (IP67 type dust / water-proof)

Water-proof type

264-625 U-WAVE-TCB (Buzzer type)

Standard

02AZF300

264-624 U-WAVE-TCB (IP67 type dust / water-proof)

Coolant-proof type

02AZF310

JSR Entech Catalogue 5 jetco@jet.co.th

jet@jet.co.th

Measuring Tools

Measurement data wireless communication system U-WAVE-TC/TM (U-WAVE fit) Type of transmission unit Measurement Data Management Convenient data collection tool and quality control software  Specifications IP67 type is resistant to water and dust. Buzzer type notifies data reception by buzzer sound and LED. Connectable measuring instruments Micrometer Caliper Order No. 264-622* 264-623* 264-620* 264-621* Model U-WAVE-TM (IP67 type) U-WAVE-TM (Buzzer type) U-WAVE-TC (IP67 type) U-WAVE-TC (Buzzer type)

Protection Rating

IP67 LEDs

N/A

IP67 LEDs

N/A

Data reception indication

Buzzer and LEDs

Buzzer and LEDs

Power supply Battery life

Lithium battery CR2032×1

Approx. 400,000 times continuous data transmission

264-622

264-621

External dimensions (mm)

41.9×12.9×38.8

56×11.45×30.4

Mass (g)

18

* Order No. differs depending on the destination country.

Add the following suffix to the order No.: K for Korea, B for Brazil and Argentina. : IP67 model is water / dust-proofed suitable for the factory floor. Buzzer type is not ware/dust-proofed.

Note

Compatibility of measuring tool and unit IP67 type is resistant to water and dust. Buzzer type notifies data reception by buzzer sound and LED. Digimatic gage Assembled appearance (Front / Back) Connecting unit Transmission unit

264-623* U-WAVE-TM (Buzzer type) 264-622* U-WAVE-TM (IP67 type) 264-621* U-WAVE-TC (Buzzer type) 264-620* U-WAVE-TC (IP67 type)

Standard

Micrometer

02AZF310

Fixed to transmission unit and inserted into output connector of Digimatic gage. Order No. 02AZF310

IP67 type

02AZF300

Protection level

IP67

N/A

Standard

02AZF300

Mass (g)

6

Caliper

Connectable transmission unit

U-WAVE-TC/TM (IP67 type)

U-WAVE-TC (Buzzer type)

IP67 type

02AZF310

* Order No. differs depending on the destination country.

Note : 02AZF310 ensures waterproof performance only when attached to measuring instruments of IP67 type.

Add the following suffix to the order No.: K for Korea, B for Brazil and Argentina.

Measurement Data Wireless Communication System U-WAVE • Data from Digimatic gages can be loaded to a PC easily. • Wireless communication eliminates cabling, improving measuring operability. • The Data Interface Function of the U-WAVE-R standard accessory software enables data input to commonly available software by keyboard input (Microsoft Excel, Notepad, etc.). Measurement Data Management Convenient data collection tool and quality control software

U-WAVE-T System Communication Specifications • Wireless communication

02AZD730G/ 02AZD730H/ 02AZD880G/ 02AZD880H 1 mW (0 dBm) or less

02AZD730J/ 02AZD880J 5 mW (7 dBm) or less

Order No.*

Transmission output Wireless specifications Wireless communication distance Wireless communication speed

U-WAVE system configuration

• USB-ITPAK V2.1

supports U-WAVE! Loading measurement data

IEEE802.15.4 base

multiple

Approx. 20 m (within visible range)

U-WAVE-Ttransfers Digimatic gage data to U-WAVE-R.

into separate Excel sheets, or simultaneous measurement using the special event drive is now available without the need for macro programming yourself. (Automatic loading in a certain interval is available with the timer function.)

U-WAVE-T

250 kbps

U-WAVE-T

DS-SS (Direct Sequence - Spread Spectrum) Resistant to interfering signals and noise 2.4 GHz band (ISM band: Universal frequency) 15 channels (2.405 to 2.475 GHz at intervals of 5 MHz) The noise search function avoids interference with other communication devices.

Modulation method

Communication frequency

Dedicated connecting cable

Connecting cable for foot switch

Used band

* Order No.

differs depending on the destination country.

Note

: To use U-WAVE-T, the conformity to the radio law of each country is required. If you use this product outside the country of purchase, please contact your dealer or nearest Mitutoyo sales office.

U-WAVE-R

A maximum of 100 Digimatic gages can be connected.

U-WAVE-R loads the data received from U-WAVE-T to a PC via USB.

Standard accessory software enables data load to Microsoft Excel.

JSR Entech Catalogue 6

jet@jet.co.th

jetco@jet.co.th

Measuring Tools

Measurement Data Wireless Communication System U-WAVE Measurement Data Management Convenient data collection tool and quality control software

• Data format Example of format when the Digimatic gage displays 12.34

■ U-WAVE-T Transmits measurement data to U-WAVE-R. Select IP67 or buzzer model, according to your application. U-WAVE-R can be connected to Digimatic gages by dedicated cable for U-WAVE-T (option). Model U-WAVE-T (IP67 type) U-WAVE-T (Buzzer type) Order No. 02AZD730G 02AZD880G Protection Rating IP67 None Data reception indication LEDs Buzzer and LEDs Power supply Lithium battery CR2032×1 Battery life Approx. 400,000 transmissions Dimensions (mm) 44×29.6×18.5 mm Mass (g) 23 g * Order No. differs depending on the destination country.

*3 Unique number assigned to U-WAVE at shipment Notes on identification of measurement data and multiple systems operation Following the above format, the U-WAVE data format starts with a 4-digit code where the first two digits represent receiver channels and the last two are transmitter channels. The large number of transmitter/ receiver combinations possible with this scheme ensures that the receivers in a factory measurement system only accept data from the intended transmitters, even when several receivers are all within communication range of different transmitters using the same channel. Different frequency bands (up to 15 available) may also be used to further ensure that there are no communication problems between adjacent U-WAVE-R units.

■ U-WAVE-T dedicated connection cable Transmits measurement data to U-WAVE-R. Select IP67 or buzzer model, according to your application. U-WAVE-R can be connected to Digimatic gages by dedicated cable for U-WAVE-T (option). A dedicated cable connects a Digimatic gage to U-WAVE-T. Check the connector (A to G; refer to pages A-25 and A-26 for details) compatible with the Digimatic gage to be used and select either standard type (figure 1) or foot switch type (figure 2) according to your application. Type Standard connecting cable Connecting cable for foot switch Order No. Order No. (A) Water-proof model with output button 02AZD790A 02AZE140A (B) Water-proof model with output button 02AZD790B 02AZE140B (C) With data-out button 02AZD790C 02AZE140C (D) 10-pin plain type 02AZD790D 02AZE140D (E) 6-pin round type 02AZD790E 02AZE140E (F) Plain type straight 02AZD790F 02AZE140F (G) Plain type straight water-proof model 02AZD790G 02AZE140G

JSR Entech Catalogue 7 jetco@jet.co.th

jet@jet.co.th

Measuring Tools

Since the standard cable clip is not sufficient to support the U-WAVE-T on a Digimatic gage, a mounting plate is provided. The mounting plate can be fixed to the gage by the easily detachable hook-and-eye type fasteners provided. Batteries can be replaced without needing to detach the U-WAVE-T from the gage. Measurement Data Wireless Communication System U-WAVE Optional Accessories for U-WAVE-T Measurement Data Management Convenient data collection tool and quality control software U-WAVE-T mounting plate

U-WAVE-T mounting plate for QM-Height Order No.02AZE990 Standard accessories • Detachable fasteners: 1 set • Mounting screw: 2 pcs

Mounting Diagram for QM-Height (02AZE990)

Mounting diagram (02AZE200)

U-WAVE-T

U-WAVE-T Mounting holes *1

Detachable fastener *2

Mounting screws

The detachable fastener is a dual lock fastener (Sumitomo 3M). It is equivalent to detachable double- faced sheet (DK-94, Scotch 3M) commercially available.

Special order U-WAVEPAK (Event drive) This is a special order product. For the latest pricing, please contact your dealer or the nearest Mitutoyo Service Center. Product configuration : Program on CD

Connecting cable

U-WAVE-T mounting plate Order No.02AZE200 Standard accessories • Detachable fasteners : 1 set • Mounting screw 2 pcs.

*1 To avoid damaging the threaded holes in the plastic body of the U-WAVE-T unit, the mounting screws should be tightened only just sufficiently to grip. Repeated removal of these screws should also be avoided for the same reason. *2 In order to avoid loss of adhesion, do not allow oil or coolant to come into contact with the bonding surfaces of the detachable fasteners.

Application examples of the mounting plate Super Caliper CD67-S15PM

QuantuMike MDE-25MX Digimatic Indicator ID-C112XB

Front view

Rear view

Front view

Rear view

Front view

Rear view

For U-WAVE-R, U-WAVE-T and U-WAVE- TC/TM, please purchase the standard model. Install this special order U-WAVE- PAK (Event drive) and gain the ability to perform setups without using the standard accessory U-WAVEPAK. A program to send a data request command is separately required to load data to a PC. Event drive supporting software: • USB-ITPAK V2.1 (timer input enabled) • MeasureReport (function key operation)

Application example of the 'Event drive' mode

For standard type U-WAVE , the currently displayed data can be sent by pressing the data switch. This is called "button drive mode". In the "event drive mode", the measurement value is checked every 0.5 seconds and measurement data is automatically sent if there is a change. At this time, the data switch is disabled. The sent data is written in the U-WAVE-R memory, and only the latest data is kept, it is not output to the PC. The data is loaded to the PC from the U-WAVE-R memory when the data request command is sent. The mode switching between "button drive" and "event drive" is enabled by the special order U-WAVEPAK (Event drive). In the event drive mode, pressing the data switch on the Digimatic gage is not necessary. PC operation enables loading data from multiple gages at once. To perform simultaneous measurement using USB-ITPAK V2.1, a special order U-WAVEPAK (Event drive) is required. Data request support from PC. Special order U-WAVEPAK (Event drive)

Note: There is no linkage between a data request sent from the PC and a data transmission from the Digimatic gage. To trigger data transmission, stop the Digimatic gage first, and then send a data request command from the PC.

Special use Event drive mode

Standard use Button drive mode

Data is sent when the button is pressed.

Data is sent if value changes (Checked every 0.5 s)

U-WAVE-R

When using the event drive please note : • The battery life is shorter than in normal mode. The battery lasts approximately 20 days with continuous use. Switching to the button mode when the battery is not in use extends the battery life. • When using several Digimatic gages (U-WAVE-T) , communication errors may occur because of radio interference in simultaneous measuring. Therefore, it is required to add U-WAVE-R and set different frequencies (15 ch) to avoid radio wave interference.

JSR Entech Catalogue 8

jet@jet.co.th

jetco@jet.co.th

Measuring Tools

Measurement Data Management Convenient data collection tool and quality control software

Measurement Data Collection Software USB-ITPAK V2.1 (IT-016U/USB-ITN/U-WAVE/DP-1VA LOGGER connectable)

USB-ITPAK V2.1 creates a procedure to input data from gages equipped with Digimatic output to Excel sheets via USB-ITN or U-WAVE. This optional software facilitates the daily inspection work for mass-produced products. The combined use with USB-ITPAK V2.1 will improve the operational efficiency of repetition inspection work. Best suited for keeping track of inspection data of mass-produced products. • Input range can be specified per Digimatic gage, which reduces improper input. • The last data input can be canceled by a single operation (foot switch, function key etc.) • Data input or cancellation can be performed at once in multiple-point simultaneous measurement. Main features of USB-ITPAK V2.0 • Setting of Microsoft Excel input : Designation of where to input (workbook, worksheet, cell range), cursor move (right, down), and others. • Selection of measuring method (3 modes available) (1) Sequential measurement (2) Simultaneous measurement (3) Individual measurement • Control item and instruction at data input • Automatically calls Excel sheet. • Cursor moves can be specified.

Order No .

USB-ITPAK V2.1

Model No. Order No.

06AFM386 * Upgrade pricing from V1.0 and V2.0 is not available. Please purchase V2.1.

USB-ITPAK V2.0 USB dongle

A USB dongle must be connected to the PC running the software.

Operating environment

Windows 2000 SP4 Windows XP SP2 or later Windows Vista

Compatible OS *1

Windows 7 Windows 8 Windows 8.1 Windows 10 Excel 2002 Excel 2003 Excel 2007 Excel 2010 Excel 2013 Excel 2016

Mouse operation

Function key

Foot switch + USB-FSW

Data switch when using U-WAVE

Data switch other than U-WAVE

Control item

Data output request

⎷ *1 ⎷ *1 ⎷ *1

⎷ *1 ⎷ *1 ⎷ *1

⎷ *2

Supported Excel versions *2

⎷ ⎷ ⎷

Data cancel Data skip

- - -

⎷ Press and hold *2

- -

Character input (example : OK or NG etc.)

⎷ Pre-registered

-

-

character strings

Language support • Operation language (15 languages) Japanese, English, German, French, Spanish, Italian, Czech, Swedish, Turkish, Polish, Hungarian, Russian, Korean, Chinese (traditional / simplified) • Operation manual (PDF file) Japanese, English, German Free space of more than 10MB CD-ROM drive For program installation USB port *3 2 ports or more Monitor resolution 800×600, 256 colors or more *1 : 32-bit, 64-bit OS supported *2 : Operation with Excel for MAC OS is not guaranteed. *3 : A commercially available hub can be used. (USB certified product is recommended) Hard disk

*1 Not available during individual measurement. *2 Not available during simultaneous measurement in the event drive mode.

• Number of connectable gages Available devices

Maximum number of connection (total of (1), (2), and (3)) For Windows 2000 /XP Up to 100 units*3 For Windows Vista /7/8/ 8.1 /10 Up to 20 units*3 For U-WAVE-R, plus 100 per unit in terms of available gages.

Others

(1) IT-016U/USB-ITN

• Maximum registration (total of (1), (2), and (3)) 400 units • Control / identification of connecting gage VCP (Virtual COM port) Switch from HID to VCP for (1) and (2). The VCP driver software is supplied with USB-ITPAK.

(2) USB-FSW (3) U-WAVE-R

Up to 100 gages can be per one unit of U-WAVE. U-WAVE-T ID: 00 to 99

USB Foot Switch Adapter USB-FSW This USB adapter for connecting a PC is required when using the Foot Switch (No. 937179T) in USB-ITN. A dedicated VCP driver* for this adapter is included in USB-ITPAK. • Measurement date/time display function (available in sequential and simultaneous measurements) The display format is subject to the setting of the Excel sheet. *3 The actual number can be less depending on the system configuration. *4 If a shorter time is set, a priority is given to the longer time compared with the actual communication time. • Data loading time : when using USB-ITN, 0.2s to 0.3s per gage unit U-WAVE event drive mode: 0.5s data refresh interval • Timer input function (only in simultaneous measurement) Input interval (time) : 0.1s *4 to 24 hours at maximum

Order No. Model No. Order No.

USB-FSW

06ADV384

Foot Switch Adapter USB-FSW

Main specification • With USB-ITPAK , application of the foot switch can be set. • Data control: “Data request”,“Data cancel”, “Data skip” • Character string input (e.g. GO/NG, etc.) *USB-FSW is used for installation of the VCP driver.

JSR Entech Catalogue 9 jetco@jet.co.th

jet@jet.co.th

Measuring Tools

Measurement Data Management Convenient data collection tool and quality control software

Measurement Data Management USB-ITPAK V2.1 (IT-016U/USB-ITN/U-WAVE/DP-1VA LOGGER connectable) More applications can be handled due to new features (Wireless (U-WAVE) support, Timer input, Measurement date/time display) Example of measurement using the U-WAVE wireless communication system — data sorting of individual measurements Data from multiple Digimatic gages (U-WAVE-T, U-WAVE-TC/TM) sent to separate Excel sheets

Loading data from multiple Digimatic gages (U-WAVE-T) into separate Excel sheets is now available without the need for macro programming.

Entry point can be specified per gage (by U-WAVE-T ID). • Specifying an Excel file: Excel Book (full path) + sheet name • Specifying data input cells (example: A1:C3) • Specifying cursor move (right or down)

The last data input may be canceled by pressing and holding the data switch Note: U-WAVE-TC / TM can also applicable.

Up to 100 gages can be handled by one U-WAVE-R unit

Example of measurement using the U-WAVE wireless communication system — timer input + measurement date/time display during simultaneous measurement

Automatically obtains displacement data in a certain input interval

If using USB-ITPAK V2.1 supporting U-WAVE event drive, arbitrary timer input is allowed without the need for macro programming.

To perform simultaneous measurement using U-WAVE, a special order U-WAVEPAK (Event drive) is required.

The input interval can be arbitrarily set by 0.1 s intervals up to 24 hours. If a smaller value than the data loading time is set, the actual measurement time will be the input interval. With U-WAVE , an error (no data) may occur if less than 0.5 s is set for the input interval. This is because the data request signal is issued before the data comes in, based on the event drive data refresh interval that is set to 0.5 s (fixed). Points to note when performing simultaneous measurement using U-WAVE and USB-ITPAK V2.1 • Besides U-WAVE, a special order U-WAVEPAK (Event drive) is required. • The battery life of U-WAVE-T becomes shorter in the event mode, reducing to approximately 20 days for continuous measurement. • When using several Digimatic gages, communication errors may occur because simultaneous transmission from all gages may cause radio interference. With U-WAVE, radio wave interference can be mostly avoided if data is transmitted after making sure there is no other radio communication. CSMA/CA method: this avoids radio interference and enables successful simultaneous data transmission of three U-WAVE-T units per U-WAVE-R. To perform simultaneous measurement with more than three units of U-WAVE-T, add U-WAVE-R and set different frequencies (15 ch) to avoid radio interference.

JSR Entech Catalogue 10

jet@jet.co.th

jetco@jet.co.th

Measuring Tools

You can set up the procedure to input the measurement data to the Excel sheet in combination with USB-ITPAK V2.1 and IT-016U/USB- ITN/U-WAVE Measurement applications of USB-ITPAK V2.1 (Three examples of how USB-ITPAK V2.1 can be deployed are shown below) Measurement Data Management USB-ITPAK V2.1 (IT-016U/USB-ITN/U-WAVE/DP-1VA LOGGER connectable) Measurement Data Management Convenient data collection tool and quality control software

Sequential measurement (Measurement example – see figure at right)

Measurement values are input one by one according to a procedure previously defined by using one or more Digimatic gages (via IT-016U/USB-ITN or U-WAVE ).

When a measuring procedure is executed, a window (as below) is dis - played. “Data request*”, “Data cancel*”, “Data skip*”, “Aborting”, “Complete” can be specified. * These operations can be allocated to the function key or foot switch (via USB-FSW ).

Simultaneous measurement Measurement values are input simultaneously from several Digimatic gages (via IT-016U/USB-ITN, U-WAVE )

Individual measurement Several operators input measurement data asynchronously according to individually defined procedures (where to input, move direction, etc.) from each Digimatic gage via IT-016U/USB-ITN or U-WAVE.

Since several individual operators perform measurement simultaneously, an operation key and a function key in the window below cannot be used at the same time. The only effective input device in this case is the foot switch (via USB-FSW ).

Notes on using USB-ITPAK V2.1: Do not merge the cells in the specified range as a measurement data input. During measurement, the Microsoft Excel worksheet cannot be modified in any way apart from entering data. If you need to modify the sheet, it is necessary to abort or finish the measurement.

JSR Entech Catalogue 11 jetco@jet.co.th

jet@jet.co.th

Measuring Tools

Measurement Data Management Convenient data collection tool and quality control software

Mini-Printer Equipped with Data Logging Function SERIES 264 — Digimatic Mini-Processor DP-1VA LOGGER

In addition to the conventional (DP-1VR) printing and statistical calculation functions, data logger and USB output functions are added and enhanced! • This is a palm-sized printer used to print measurement data from Digimatic gages or to perform statistical analysis. • The versatile DP-1VA LOGGER printer not only prints measurement data, but performs a variety of statistical analyses, draws histograms and D-charts and also performs complex operations on Xbar-R control charts. • The data logger function allows storage of up to 1,000 pieces of data in memory, and batch transfer of stored data to an Excel-format inspection certificate, etc., by connecting to a PC with a USB cable (optional).

Specifications • Order No. : 264-505E • Model : DP-1VA LOGGER • Data input : Digimatic input, RS-232C input (specific to Mitutoyo KA counter) • Data processing capacity: 10 9,999 subgroups = 99,990 pieces of data • GO/±NG judgment (five sets can be defined) • Output : (1) USB output (2) RS-232C data output at TTL levels (3) GO/±NG judgment result out put (−NG, GO, +NG) • Input timer : Input intervals Mode 0 : 100,000 pieces of data Modes 1,2 : 9,999 pieces of data Mode 3 : Sample size • Printing method : Thermal line printer • Printing speed : 0.8 s per line (6.5 mm/s) (using AC adapter) • Printing line : 10,000 lines of normal characters per roll 7,000 lines of large characters per roll • Printing paper : High durability thermo- sensitive paper Note : Printed characters do not fade if a printout is stored in a cool dark place, but if it is to be used for official documents, or stored more than 5 years, it is recommended to make a more durable copy. • Power supply : 2 power methods (1) AC adapter 100-240 V 50/60 Hz AC 0.25 s, 1 s, 5 s, 30 s, 1 min, 30 min, 60 min Width 58 mm × length 48 m adapter (6 V, 2 A) as a standard accessory. (2) 4 pcs. of LR6/ AA size (alkaline or Ni-Mh) Note : Manganese dioxide batteries are not usable. • Battery life: About 10,000 lines (if data is printed once every 5 seconds using 1,600 mA NiMH batteries at 20 ℃ ) Note : This is a typical value and is not guaranteed. • External dimensions: 94 (W) × 201 (D) × 75.2 (H) mm (1) USB cable (A-microB) : 06AFZ050 (1 m) (2) RS-232C output cable : 09EAA084 (1 m, D-SUB 9 pin) (3) RS-232C counter cable : 09EAA094 Cable for KA counter (1 m, D-SUB 25-pin) (4) GO/ ±NG judgment cable : 965516 (2 m, 10 pin terminal / separate) (5) Foot switch: 937179T Consumable Items Printing paper (10 rolls) : 09EAA082 • Mass: 390 g (main unit) Optional Accessories

264-505E DP-1VA LOGGER

Example of printout

Example of batch printing log data In OUTLOG Setting 1

MODE1

MODE2

MODE3

Various statistical calculations are executed using all input data. If the tolerance limits have been set, GO/±NG judgment and histogram creation are also enabled.

In addition to the MODE1 function, measurements within the tolerance limits are printed out as a D chart*. This chart allows you to identify the trend of variations in measurement data. * D chart stands for Displacement chart.

Only input of data automatically enables calculation processing of complex control limit values as well as calculation for creating an Xbar-R control chart.

In OUTLOG Setting 2 This setting allows printout of measurement time, measurement value, and GO/±NG judgment result.

In OUTLOG Setting 3 This setting allows printout of data number, measurement value, and GO/±NG judgment result.

This setting allows printout of data number, measurement date and time, and GO/±NG judgment result.

Statistical calculation data

MODE0

MODE1, 2

MODE3

GO/±NG judgment

N : Number of pieces of data

N : Number of pieces of data

MAX : Maximum value MIN : Minimum value R : Range X _ : Mean value δ n : Standard deviation of a population (N) δ n-1 : Sample standard deviation (N-1) –NG : For the number of pieces of data smaller than the lower limit +NG : For the number of pieces of data larger than the upper limit P : Percentage of rejects

MAX : Maximum value MIN : Minimum value

n : Number of subgroups (up to 10) X _ : Mean value in a subgroup R : Range of a subgroup X _ : Mean value

X _ -UCL : Upper control limit X _ -LCL : Lower control limit R : Center (R control)

R-UCL : Upper control limit (R control) R-LCL : Lower control limit (R control)

Cp : Maximum process capability potential Cpk : Actual process capability achieved

JSR Entech Catalogue 12

jet@jet.co.th

jetco@jet.co.th

Measuring Tools

Measurement Data Management Convenient data collection tool and quality control software

Digimatic/RS-232C Interface Unit Multiplexer MUX-10F

Specifications • Order No.: 264-002E • Model: MUX-10F • Data input port: 4 channels for Digimatic gages • Output: (RS-232C) • Data output Via RS-232C interface : Data transmission method : Half-duplex Data transmission code : ASCII / JIS Data length : 8 bits Parity check : None Stop bit : 1 Data transmission speed : 300/600/1200/2400/9600/19200 bps • Connector specification:

• Multiplexer MUX-10F is a measurement data transfer device that converts incoming Digimatic output measurement data to RS-232C and outputs it to an external device such as a PC. • Up to four measuring instruments with Digimatic output can be connected.

264-002E MUX-10F

Usage Example Data input using the data button on the Digimatic gage • If the Digimatic gage has a data button, data is sent to the MUX-10F from the gage, converted to RS-232C and sent out. Data input using the load switch • If the Digimatic gage does not have a data button, or when simultaneous measurements are performed, the MUX-10F load switch is used to poll data from the measuring gage (s) selected by the tool selection switch (es), converted to RS-232C , and sent out. • If multiple measuring gages are selected by the tool selection switch, data is input in the order of channels 1 through 4. • Optional foot switch (937179T) is available for quick data entry.

Pin No. Signal

Function

in/out

1 2 3 4 5 6 7 8

CD

out

RD Received data out

Communication data

TD

in

GND Ground

DR

out

CS

out

9 Note : For connection with a PC, use a commercially available RS-232C straight cable.

• Data format

Data input using the external commands • Data from a specified measuring gage connected to MUX-10F can be polled (ch 1- 4) by inputting a command from the PC. Commands (ASCII) Transfer channels 1 (ASCII code31) CR 1 2 (ASCII code32) CR 2 3 (ASCII code33) CR 3 4 (ASCII code34) CR 4 *A (ASCII code41) CR 1, 2, 3, 4 *B (ASCII code42) CR 1, 2, 4 *C (ASCII code43) CR 1, 3, 4 *D (ASCII code44) CR 2, 3, 4 E (ASCII code45) CR 1, 2, 3 F (ASCII code46) CR 1, 2 G (ASCII code47) CR 1, 3 H (ASCII code48) CR 1, 4 I (ASCII code49) CR 2, 3 J (ASCII code50) CR 2, 4 K (ASCII code51) CR 3, 4 * Command will operate the same as previous MUX-10 when 4-channel mode is turned off.

• Power supply: AC adapter (9 V, 500 mA) • External dimensions: 91.4 (W) × 92.5 (D) × 50.4 (H) mm Note : Communication software is not included.

JSR Entech Catalogue 13 jetco@jet.co.th

jet@jet.co.th

Measuring Tools

Measurement Data Management Convenient data collection tool and quality control software

Digimatic Data Cable Selector (including USB Input Tool Direct)

JSR Entech Catalogue 14

jet@jet.co.th

jetco@jet.co.th

Measuring Tools

Digimatic Data Cable Selector (including USB Input Tool Direct) Measurement Data Management Convenient data collection tool and quality control software

JSR Entech Catalogue 15 jetco@jet.co.th

jet@jet.co.th

Page i Page ii Page iii Page iv Page v Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90 Page 91 Page 92 Page 93 Page 94 Page 95 Page 96 Page 97 Page 98 Page 99 Page 100 Page 101 Page 102 Page 103 Page 104 Page 105 Page 106 Page 107 Page 108 Page 109 Page 110 Page 111 Page 112 Page 113 Page 114 Page 115 Page 116 Page 117 Page 118 Page 119 Page 120 Page 121 Page 122 Page 123 Page 124 Page 125 Page 126 Page 127 Page 128 Page 129 Page 130 Page 131 Page 132 Page 133 Page 134 Page 135 Page 136 Page 137 Page 138 Page 139 Page 140 Page 141 Page 142 Page 143 Page 144 Page 145 Page 146 Page 147 Page 148 Page 149 Page 150 Page 151 Page 152 Page 153 Page 154 Page 155 Page 156 Page 157 Page 158 Page 159 Page 160 Page 161 Page 162 Page 163 Page 164 Page 165 Page 166 Page 167 Page 168 Page 169 Page 170 Page 171 Page 172 Page 173 Page 174 Page 175 Page 176 Page 177 Page 178 Page 179 Page 180 Page 181 Page 182 Page 183 Page 184 Page 185 Page 186 Page 187 Page 188 Page 189 Page 190 Page 191 Page 192 Page 193 Page 194 Page 195

www.jet.co.th

Powered by